spr optical biosensor Search Results


90
Biacore spr optical biosensor
Spr Optical Biosensor, supplied by Biacore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/spr optical biosensor/product/Biacore
Average 90 stars, based on 1 article reviews
spr optical biosensor - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Janssen nanobead enhanced optical fiber spr biosensor
Nanobead Enhanced Optical Fiber Spr Biosensor, supplied by Janssen, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/nanobead enhanced optical fiber spr biosensor/product/Janssen
Average 90 stars, based on 1 article reviews
nanobead enhanced optical fiber spr biosensor - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Integrated Fluidics six-channel portable optical (spr) biosensor
Six Channel Portable Optical (Spr) Biosensor, supplied by Integrated Fluidics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/six-channel portable optical (spr) biosensor/product/Integrated Fluidics
Average 90 stars, based on 1 article reviews
six-channel portable optical (spr) biosensor - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Biacore optical biosensors based on surface plasmon resonance (spr) spectroscopy
Optical Biosensors Based On Surface Plasmon Resonance (Spr) Spectroscopy, supplied by Biacore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/optical biosensors based on surface plasmon resonance (spr) spectroscopy/product/Biacore
Average 90 stars, based on 1 article reviews
optical biosensors based on surface plasmon resonance (spr) spectroscopy - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Mebios GmbH fiber optic spr biosensor
Fiber Optic Spr Biosensor, supplied by Mebios GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fiber optic spr biosensor/product/Mebios GmbH
Average 90 stars, based on 1 article reviews
fiber optic spr biosensor - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Photonics Inc fiber optic spr-based uric acid biosensor
Fiber Optic Spr Based Uric Acid Biosensor, supplied by Photonics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fiber optic spr-based uric acid biosensor/product/Photonics Inc
Average 90 stars, based on 1 article reviews
fiber optic spr-based uric acid biosensor - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Electro-Optical Systems Inc electro-optical spr biosensor
Illustration of a <t>SPR</t> <t>biosensor</t> based on the Kretschmann configuration.
Electro Optical Spr Biosensor, supplied by Electro-Optical Systems Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/electro-optical spr biosensor/product/Electro-Optical Systems Inc
Average 90 stars, based on 1 article reviews
electro-optical spr biosensor - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Graffinity Pharmaceuticals GmbH spr optical-biosensor systems
Illustration of a <t>SPR</t> <t>biosensor</t> based on the Kretschmann configuration.
Spr Optical Biosensor Systems, supplied by Graffinity Pharmaceuticals GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/spr optical-biosensor systems/product/Graffinity Pharmaceuticals GmbH
Average 90 stars, based on 1 article reviews
spr optical-biosensor systems - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Biacore biosensor system using the optical spr phenomenon
Illustration of a <t>SPR</t> <t>biosensor</t> based on the Kretschmann configuration.
Biosensor System Using The Optical Spr Phenomenon, supplied by Biacore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/biosensor system using the optical spr phenomenon/product/Biacore
Average 90 stars, based on 1 article reviews
biosensor system using the optical spr phenomenon - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Pengqi Technology Development Co Ltd modeling of a highly sensitive mos2-graphene hybrid based fiber optic spr biosensor for sensing dna hybridization
Illustration of a <t>SPR</t> <t>biosensor</t> based on the Kretschmann configuration.
Modeling Of A Highly Sensitive Mos2 Graphene Hybrid Based Fiber Optic Spr Biosensor For Sensing Dna Hybridization, supplied by Pengqi Technology Development Co Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/modeling of a highly sensitive mos2-graphene hybrid based fiber optic spr biosensor for sensing dna hybridization/product/Pengqi Technology Development Co Ltd
Average 90 stars, based on 1 article reviews
modeling of a highly sensitive mos2-graphene hybrid based fiber optic spr biosensor for sensing dna hybridization - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Optik GmbH mos2graphene hybrid based fiber optic spr biosensor
Illustration of a <t>SPR</t> <t>biosensor</t> based on the Kretschmann configuration.
Mos2graphene Hybrid Based Fiber Optic Spr Biosensor, supplied by Optik GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/mos2graphene hybrid based fiber optic spr biosensor/product/Optik GmbH
Average 90 stars, based on 1 article reviews
mos2graphene hybrid based fiber optic spr biosensor - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Texas Instruments ti-spr-1 optical biosensor system
Illustration of a <t>SPR</t> <t>biosensor</t> based on the Kretschmann configuration.
Ti Spr 1 Optical Biosensor System, supplied by Texas Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/ti-spr-1 optical biosensor system/product/Texas Instruments
Average 90 stars, based on 1 article reviews
ti-spr-1 optical biosensor system - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


Illustration of a SPR biosensor based on the Kretschmann configuration.

Journal: Sensors (Basel, Switzerland)

Article Title: Role of Graphene in Surface Plasmon Resonance-Based Biosensors

doi: 10.3390/s24144670

Figure Lengend Snippet: Illustration of a SPR biosensor based on the Kretschmann configuration.

Article Snippet: In an innovative approach, an electro-optical SPR biosensor was developed using graphene within a Kretschmann–Raether configuration [ ].

Techniques:

PICOS framework was used to structure the research question.

Journal: Sensors (Basel, Switzerland)

Article Title: Role of Graphene in Surface Plasmon Resonance-Based Biosensors

doi: 10.3390/s24144670

Figure Lengend Snippet: PICOS framework was used to structure the research question.

Article Snippet: In an innovative approach, an electro-optical SPR biosensor was developed using graphene within a Kretschmann–Raether configuration [ ].

Techniques: SPR Assay, Comparison

The number of documents identified by searching: “graphene properties and applications” (black) and “integration of graphene in SPR sensors” (blue). Data were obtained from the Scopus database.

Journal: Sensors (Basel, Switzerland)

Article Title: Role of Graphene in Surface Plasmon Resonance-Based Biosensors

doi: 10.3390/s24144670

Figure Lengend Snippet: The number of documents identified by searching: “graphene properties and applications” (black) and “integration of graphene in SPR sensors” (blue). Data were obtained from the Scopus database.

Article Snippet: In an innovative approach, an electro-optical SPR biosensor was developed using graphene within a Kretschmann–Raether configuration [ ].

Techniques:

Interventions considering the type of  biosensor,  graphene integration method, and  SPR  configuration.

Journal: Sensors (Basel, Switzerland)

Article Title: Role of Graphene in Surface Plasmon Resonance-Based Biosensors

doi: 10.3390/s24144670

Figure Lengend Snippet: Interventions considering the type of biosensor, graphene integration method, and SPR configuration.

Article Snippet: In an innovative approach, an electro-optical SPR biosensor was developed using graphene within a Kretschmann–Raether configuration [ ].

Techniques: Refractive Index, Transmission Assay, Binding Assay, Adsorption, Titanium Dioxide, Modification

Performance metrics of graphene-based  SPR  biosensors.

Journal: Sensors (Basel, Switzerland)

Article Title: Role of Graphene in Surface Plasmon Resonance-Based Biosensors

doi: 10.3390/s24144670

Figure Lengend Snippet: Performance metrics of graphene-based SPR biosensors.

Article Snippet: In an innovative approach, an electro-optical SPR biosensor was developed using graphene within a Kretschmann–Raether configuration [ ].

Techniques: Amplification, Adsorption, Concentration Assay, Refractive Index, Control, Clinical Proteomics, Virus, Modification, Transmission Assay, Imaging, Preserving, Microscopy, Electron Microscopy, Sample Prep, Spectroscopy

Distribution of qualitative evaluations for performance metrics in graphene-based SPR biosensors. ( a ) Sensitivity improvements, ( b ) specificity enhancements, and ( c ) stability advancements. Each panel represents the proportion of studies reporting different levels of performance enhancement: improved, enhanced, significant, highest, high, higher, ultra stable, and not specified.

Journal: Sensors (Basel, Switzerland)

Article Title: Role of Graphene in Surface Plasmon Resonance-Based Biosensors

doi: 10.3390/s24144670

Figure Lengend Snippet: Distribution of qualitative evaluations for performance metrics in graphene-based SPR biosensors. ( a ) Sensitivity improvements, ( b ) specificity enhancements, and ( c ) stability advancements. Each panel represents the proportion of studies reporting different levels of performance enhancement: improved, enhanced, significant, highest, high, higher, ultra stable, and not specified.

Article Snippet: In an innovative approach, an electro-optical SPR biosensor was developed using graphene within a Kretschmann–Raether configuration [ ].

Techniques:

Integration of graphene into SPR biosensors. This figure illustrates the key components and configurations involved in integrating graphene into SPR biosensors. The nodes and their abbreviations are as follows: graphene (Graphene), SPR biosensors (SPR Bio.), gold thin film (Gold TF), silver layer (Silver L), biomolecular interactions (Bio. Interactions), electric field amplification (E-Field Ampl.), Kretschmann configuration (Kretschmann Config.), periodic dielectric subwavelength grating (Periodic Grating), graphene oxide (GO), molybdenum disulfide (MoS2), high-index chalcogenide core fiber (Chalcogenide Fiber), multilayer structure (Multilayer Struct.), and elliptic-circular nanodisk resonators (Nanodisk Res.). The edges depict the relationships and interactions between these components, emphasizing the enhanced performance and capabilities of SPR biosensors through the incorporation of graphene.

Journal: Sensors (Basel, Switzerland)

Article Title: Role of Graphene in Surface Plasmon Resonance-Based Biosensors

doi: 10.3390/s24144670

Figure Lengend Snippet: Integration of graphene into SPR biosensors. This figure illustrates the key components and configurations involved in integrating graphene into SPR biosensors. The nodes and their abbreviations are as follows: graphene (Graphene), SPR biosensors (SPR Bio.), gold thin film (Gold TF), silver layer (Silver L), biomolecular interactions (Bio. Interactions), electric field amplification (E-Field Ampl.), Kretschmann configuration (Kretschmann Config.), periodic dielectric subwavelength grating (Periodic Grating), graphene oxide (GO), molybdenum disulfide (MoS2), high-index chalcogenide core fiber (Chalcogenide Fiber), multilayer structure (Multilayer Struct.), and elliptic-circular nanodisk resonators (Nanodisk Res.). The edges depict the relationships and interactions between these components, emphasizing the enhanced performance and capabilities of SPR biosensors through the incorporation of graphene.

Article Snippet: In an innovative approach, an electro-optical SPR biosensor was developed using graphene within a Kretschmann–Raether configuration [ ].

Techniques: Amplification

Summary of target analytes studied with graphene-enhanced SPR biosensors.

Journal: Sensors (Basel, Switzerland)

Article Title: Role of Graphene in Surface Plasmon Resonance-Based Biosensors

doi: 10.3390/s24144670

Figure Lengend Snippet: Summary of target analytes studied with graphene-enhanced SPR biosensors.

Article Snippet: In an innovative approach, an electro-optical SPR biosensor was developed using graphene within a Kretschmann–Raether configuration [ ].

Techniques: